Selection EEG Electrode Positions for Epilepsy Seizure Detection Using Total Power Spectrum and Machine Learning
Downloads
Detecting epileptic seizures poses significant challenges due to the complex and variable nature of EEG signals, particularly when aiming for implementation in wearable devices. The use of 64-channel EEG electrodes, while comprehensive, is impractical for wearable applications due to their size, cost, and the high computational load required for processing. The use of a single-channel EEG wearable device offers notable advantages, including reduced size and cost, making it more practical and comfortable for continuous monitoring in daily life. Additionally, the lower computational load enhances battery life and allows for real-time data processing, which is critical for timely seizure detection and intervention. This research investigates the detection of epileptic seizures using various machine learning algorithms and the power spectrum feature extraction method from EEG signals, aiming for application in wearable devices with a single-channel electrode. The study applied random forest (RF), K-nearest neighbor (KNN), decision tree (DF), support vector mechine (SVM), and logistic regression algorithms to assess their effectiveness. Results revealed that the power spectrum extraction method notably improved seizure detection accuracy, with RF and KNN achieving 93% and 92% accuracy respectively when using all EEG channels. When limited to a single channel, SVM demonstrated the highest accuracy of 82% with channel 3. These findings underscore the efficacy of the power spectrum method for EEG signal processing, providing significant improvements in accuracy and computational efficiency. The study concludes that the proposed approach is promising for enhancing epileptic seizure detection, suggesting further optimization for real-time application in wearable devices to develop accurate and efficient diagnostic tools.
Copyright (c) 2024 Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics

This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.
Authors who publish with this journal agree to the following terms:
- Authors retain copyright and grant the journal right of first publication with the work simultaneously licensed under a Creative Commons Attribution-ShareAlikel 4.0 International (CC BY-SA 4.0) that allows others to share the work with an acknowledgement of the work's authorship and initial publication in this journal.
- Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgement of its initial publication in this journal.
- Authors are permitted and encouraged to post their work online (e.g., in institutional repositories or on their website) prior to and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published work (See The Effect of Open Access).





