Data Communication Stability Test a Data Acquisition System (DAQ) for Inpatient Rooms

DAQ, CovWatch, Connectivity, Inpatient Rooms, smartphone

Authors

  • Sentagi Sesotya Utami
    trilestari@pnp.ac.id
    Department of Nuclear and Physics Engineering, Faculty of Engineering, Universitas Gadjah Mada, Indonesia , Indonesia
  • Winny Setyonugroho Department Hospital Administration, School of Postgraduate, Universitas Muhammadiyah Yogyakarta, Indonesia, Indonesia
  • Iman Permana Department of Nursing, School of Postgraduate, Universitas Muhammadiyah Yogyakarta, Indonesia, Indonesia
  • Tri Lestari Department of Information Technology, Politeknik Negeri Padang, Indonesia, Indonesia
  • Muhammad Dian Saputra Taher Department of Anthropology, Faculty of Cultural Sciences, Universitas Gadjah Mada, Indonesia, Indonesia
  • Akhmad Khanif Department of Anthropology, Faculty of Cultural Sciences, Universitas Gadjah Mada, Indonesia, Indonesia
  • Gilang Ari Widodo Utomo Department of Electrical Engineering, Faculty of Engineering, Universitas Muhammadiyah Yogyakarta, Indonesia, Indonesia
August 15, 2025
August 17, 2025

Downloads

In inpatient services, the patient's bed is usually limited by a curtain or partition to maintain patient safety. At the time of data collection, obstacles or obstacles were considered as a result of effectiveness and validation of medical device sensor data. This study aims to explain the results of testing the reliability of Bluetooth and internet on CovWatch hardware and applications. This research is an action research; used comparisons using devices (tools) with different specifications. Testing internet and Bluetooth connectivity from the CovWatch unit and applications installed on the Samsung A01, Redmi Note 10 and Oppo A57 devices, the results were mixed. Measurement of the range of connectivity is carried out using a barrier (Selected Semi PVC, Multiplex, Kalsiboard) and without a barrier. The results of this experiment show that the CovWatch Hardware and Samsung A01 are considered the best at obtaining vital sign data, while the Redmi Note 10 and OPPO A57 are not good because some data cannot be obtained so they do not appear on the monitor unit. This test identifies obstructions and optimal distances that can be used to provide data quickly, adopting innovative, flexible and integrated care delivery models to ensure optimal continuity and access.

How to Cite

Utami, S. S., Setyonugroho, W., Permana, I., Lestari, T., Taher, M. D. S., Khanif, A., & Utomo, G. A. W. (2025). Data Communication Stability Test a Data Acquisition System (DAQ) for Inpatient Rooms . Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics, 5(1), 60-65. https://doi.org/10.35882/ijeeemi.v5i1.162